Specification |
Poorten & interfaces |
---|
Ondersteunde opslagstationinterfaces | SAS, SATA | Interne SAS-poorten | 3 | Hostinterface | PCI Express x8 | PCI Express slots versie | 4.0 | Prestatie |
---|
Soorten RAID | 0, 1, 5, 6, 10, 50, 60 | SSD-ondersteuning | Ja | S.M.A.R.T. support | Ja | Overdrachtssnelheid | 6 Gbit/s | Number of devices supported | 240 | Mean time between failures (MTBF) | 3000000 uur | Vormfactor | MD2 | Certificering | Australia/New Zealand RCM (AS/NZS CISPR 32; CISPR 32:2015, Class A; AS/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN/CSA C22.2 No. 62368-1-14), USA/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3/2015.04, Class A; V-4/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020) | Aantal kanalen | 24 kanalen | Data-uitwisseling |
---|
Overdrachtssnelheid | 6 Gbit/s | Technische details |
---|
Soorten RAID | 0, 1, 5, 6, 10, 50, 60 | SSD-ondersteuning | Ja | S.M.A.R.T. support | Ja | Number of devices supported | 240 | Vormfactor | MD2 | Aantal kanalen | 24 kanalen | Duurzaamheidscertificaten | RoHS, WEEE | Compliance certificates | RoHS, WEEE | Design |
---|
Vormfactor | MD2 | Duurzaamheid |
---|
Mean time between failures (MTBF) | 3000000 uur | Energie |
---|
Stroomverbruik (typisch) | 24 W | Certificaten |
---|
Certificering | Australia/New Zealand RCM (AS/NZS CISPR 32; CISPR 32:2015, Class A; AS/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN/CSA C22.2 No. 62368-1-14), USA/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3/2015.04, Class A; V-4/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020) | Minimale systeemeisen |
---|
Ondersteunde server operating systems | SUSE Linux Enterprise Server | Ondersteunt Windows | Ja | Ondersteunt Linux | Ja | Andere ondersteundende systemen | VMware vSphere ESXi | Eisen aan de omgeving |
---|
Bedrijfstemperatuur (T-T) | 0 - 55 °C | Relatieve vochtigheid in bedrijf (V-V) | 5 - 90 procent | Gewicht en omvang |
---|
Breedte | 155,6 mm | Diepte | 111,1 mm | Overige specificaties |
---|
Andere ondersteundende systemen | VMware vSphere ESXi |
|